Faq - EXEO
1 ) The door works at reduced speed - The opening commands for disabled people are active (the leds HA, HB are on)
1.1) Check the functioning of opening commands for disabled people.
2 ) The door starts and stops with jerky movements - The protection sensors are on
2.1) Check the adjustments and the orientation of the sensor. Remove any objects that are present.
3 ) The door does not stop - The opening radars are active (the leds 3A, 3B are on)
3.1) Check the adjustments and the orientation of the sensor. Remove any moving objects.
4 ) The door does not move - The safety contacts are open
4.1) Make sure the connection is sound or that all the safety devices have been safety devices have been correctly overridden (red leds 6A, 6B, 6C, 9E must be off)
5 ) The door does not move - The function selector is in the door closed position or in the night-time closure position (red led 9 is on)
5.1) Change the selected function.
6 ) The door does not move - The door wings have collapsed
6.1) Lock the door wing in the correct position.
7 ) The door does not move - No power supply (POWER ALARM LED off)
7.1) Check that there is mains electricity.
8 ) The door does not move - No opening commands are received
8.1) Check that the radars are powered and correctly functioning.
8.2) Check that the function selector is correctly connected.

Türkçe
Italiano
Français
Deutsch
Español
Русский
English